material | metal mesh |
Filtering accuracy | 3 microns |
Installation position | oil pump outlet |
Filter medium | phosphate ester fire-resistant oil |
Replacement condition | When the equipment alarms, the filter element needs to be removed and replaced |
If you have any other customization needs, please do not hesitate to contact us and we will provide you with a solution.
The replacement steps for EH oil pump discharge filter AP1E101-01D03V/-WF mainly include the following:
1. Firstly, it is necessary to stop the operation of the EH oil main pump and close the inlet and outlet valves. Disconnect the power or unplug the plug.
2. Find the position of the EH oil pump discharge filter AP1E101-01D03V/-WF at the outlet of the fire resistant main oil pump, usually located at the outlet of the fire resistant main oil pump. It may be necessary to use tools to remove the protective cover or cover.
3. Use a suitable tool, such as a wrench, to remove the outer shell of the filter element. Generally, it is a threaded connection and can be disassembled clockwise.
4. Remove the old oil filter element and check its condition. If there is serious pollution or damage, the filter element should be replaced immediately.
5. Use a clean cloth or tissue to clean the filter housing and filter seat, ensuring that there are no debris left.
6. Install a new EH oil pump discharge filter AP1E101-01D03V/-WF in the direction of the arrow on the filter element housing, taking care not to be too tight or loose.
7. Reinstall the filter element housing and tighten it counterclockwise, but do not use excessive force.
8. Open the inlet and outlet valves, power on and start the fire resistant oil main pump to ensure the normal operation of the fire resistant oil main pump.
9. Check if there is any oil leakage from the shell and seat of the filter element. If any oil leakage is found, it should be promptly eliminated.
10. Record the date and mileage of filter replacement in the maintenance log for future maintenance.