Bladder accumulators are widely favored by hydraulic system users for their high efficiency, compactness and reliability. This article will take a deep look at how the bladder accumulator NXQA-1.6/20-L-A stores energy through pressurization, and the key aspects that should be focused on during regular inspections to ensure its long-term effective operation.
The core of the bladder accumulator NXQA-1.6/20-L-A is its internal elastic bladder, which is made of special synthetic rubber and has excellent pressure and temperature resistance. During the pressurization process, the accumulator bladder is filled with high-pressure gas (usually nitrogen) and the outside of the bladder is filled with hydraulic oil. When the system pressure is lower than the preset value, the high-pressure gas in the bladder releases the stored energy back to the hydraulic system by compressing the hydraulic oil, thereby quickly replenishing the system pressure and improving the response speed.
Specifically, the nominal volume of the NXQA-1.6/20-L-A accumulator is 1.6 liters and the maximum working pressure is 20MPa. When the system pressure drops, the high-pressure nitrogen in the accumulator bladder expands, pushing the hydraulic oil into the system, and vice versa. This two-way energy exchange mechanism enables the accumulator to store and release energy without additional energy input.
In order to ensure the effective operation of the accumulator bladder NXQA-1.6/20-L-A, regular inspection is an essential link. The following are several main inspection aspects:
- Bladder integrity inspection: Check whether the bladder has cracks, aging or signs of damage. Any slight damage may cause gas leakage and affect the performance of the accumulator.
- Gas pressure check: Use a special pressure gauge to check whether the gas pressure in the bladder meets the specified pre-charge pressure. If the pressure is insufficient, nitrogen should be added to the standard value in time to maintain the energy storage capacity of the accumulator.
- Connection sealing inspection: Check the sealing ring at the connection between the accumulator and the hydraulic system to ensure that there is no leakage. Any leakage may cause a pressure drop and affect the normal operation of the system.
- Appearance inspection: Check whether the accumulator shell has rust, dents or cracks, which may be external manifestations of abnormal internal pressure.
- Functional test: Under safe conditions, the accumulator is pressure cycled to verify its responsiveness and sealing performance under different pressures.
During the inspection, if the bladder is found to be severely aged or damaged, or the accumulator cannot achieve the expected performance, the bladder should be replaced immediately. The replacement process should follow the manufacturer’s instructions to ensure that the new bladder is compatible with the original equipment and is properly pressurized to restore the full functionality of the accumulator.
Yoyik offers various types of valves and pumps and its spare parts for power plants:
Cooling fan YP2-90L-2
Mechanical seal M74N-140
Oring A156.33.01.10-18X2.4
Overspeed protection control valve 165.31.56.03.01
Journal Bearing HZB200-430-02-08
Lubricating oil pump seal kit LDX36-95
VALVE SOLENOID: 54292023
Isolation valve F3DG5S2-062A-220DC50-DFZK-V/B08
BLADDER NXQ-AB-40/20 L
accumulator seal kit NXQ A40/31.5-L
coil MCSC-J-230-A-G0-0-00-10
Coil for Solenoid Valve MP-C-089
HP metal hose 16G2AT-HMP(DN25)-DK025-1400
coil solenoid 220v Z2805013
Seal retaining ring 4Pcs // spacer ring P19182D-00 P19182D-00
vacuum chamber and pump 30-WS
vacuum pump Valve bolt P-1764-1
shutoff valve types WJ15F1.6P
servovalves FRD.WJA5.021
Servo valve 072-1203-10
Post time: Jun-26-2024