The AD card AC6682 is an analog-to-digital conversion card used in the excitation system of power plants. It is a data acquisition device responsible for converting analog signals into digital signals.

CPU board PCA-6743VE (3)

The application of AD conversion card AC6682 in excitation system is mainly for high-precision monitoring and control of key analog signals during generator operation, such as voltage, current, etc. These signals reflect the operating status of the generator and are crucial for ensuring its stable operation and protection system. Through the AD card, the excitation system can collect real-time analog signals such as generator excitation voltage, excitation current, and generator outlet voltage, and convert these analog signals into digital signals, which are then sent to the computer or controller for processing and analysis. In this way, the control system can accurately adjust the excitation current based on these digital information to respond to changes in the demand of the power grid, maintain voltage stability of the generator, participate in reactive voltage regulation of the power system, and static stability control of the generator.

 

The AD conversion card AC6682 has the characteristics of high resolution, high sampling rate, and low noise to adapt to the rapidly changing and high-precision signal processing requirements in the power system.

CPU board PCA-6743VE (2)

AD conversion card AC6682 has the following features:

  • Resolution and sampling rate: This AD card has a 12 bit analog-to-digital conversion resolution, which means it can divide analog signals into 4096 (2 ^ 12) quantization levels, providing a more delicate signal measurement accuracy. Meanwhile, its sampling rate is as high as 1MHz, which means it can collect 1 million samples per second, making it suitable for real-time capture and analysis of high-speed signals.
  • Number of input channels: It is configured with 32 single ended input channels, which allows the card to collect data from 32 different signal sources simultaneously, making it very suitable for application scenarios that require a large amount of parallel data collection, such as multi-point temperature monitoring, voltage monitoring, etc.
  • Input voltage range: It supports three standard input voltage ranges, including 5V, 10V and ± 5V. This design enables the AD card to adapt to a variety of different signal levels, meet the input requirements of different sensors or devices, and increase its versatility.
  • Data storage and sampling length: Supports data storage sampling, with a maximum sampling length of 1024K points, which means it can record up to 1024000 samples of data at once. This is very useful for long-term data recording or analyzing signals with longer cycles.
  • Switching input: In addition to analog signal acquisition, this AD card also integrates 24 programmable switching inputs, which can be used to monitor digital status signals, such as equipment status, alarm signals, etc., further expanding its application range.

Control board ME8.530.014 V2-5 (1)

Yoyik can offer many spare parts for power plants as below:
TEMPERATURE SENSOR WZP230-150
Braun Card D421.51U1
pressure switch CMS-I 0.35MPa
proximity sensor TM0182-A50-B01-C00
Torque Control Module SY-JB (Ver 2.10)
CABLE CONNECTOR 10SL-4
relay SJ-12D
Pressure Differential Switch RC771BZ090H
Level Gauge AL501-D51002
LIMIT SWITCH YBLXW-5/11G2
switch giật sự cố HKLS-II
Integrator Analog Input Board 421400688
CONVERTER GD2131007
Flame TV tube SXJZ-70C
DP PRESSURE SWITCH Z1201420
Travel transmitter LTM-3A-I
REUGER pressure gauge PBX-100-LA
PRESSURE SWITCH BH-003001-003
Cable support XY2CZ705


  • Previous:
  • Next:

  • Post time: May-28-2024