UHZ-618C17 magnetic flap level gauge often malfunctions in practical applications. Some of these malfunctions are caused by a single component failure, while others are caused by multiple components simultaneously, such as common display panel display abnormalities.

Magnetic Liquid Level Indicator UHZ-519C (6)

The following is Yoyik’s summary of the causes of abnormal display on the UHZ-618C17 level gauge panel. There are usually several reasons for this type of fault:

1. The gap design between the flipper and the guide rail is unreasonable or too small, resulting in excessive friction and the flipper not flipping;

2. The distance between the display panel and the float is too large, and the magnetic steel driving force of the float is insufficient, resulting in abnormal flipping;
Magnetic Liquid Level Indicator UHZ-519C (5)

3. The magnetic steel in the flip is too small or the magnetic force disappears, resulting in the flip not flipping or abnormal flipping;

4. Impurities such as water or dust seep into the display panel, causing difficulty in flipping and flipping;

5. The environmental temperature is too low, causing the medium to freeze, the float cannot move, and the flipping plate cannot display the liquid level normally.
Magnetic Liquid Level Indicator UHZ-519C (2)

Other regular types of UHZ series level gauges:
Magnetic Liquid Level Indicator UHZ-10C00N
Magnetic Level Indicator UHZ-10C07B
Magnetic Liquid Level Indicator UHC-DB
LEVEL GAUGE UHZ-510CLR
Magnetic Liqid Level Indicator UHZ-DB
Liqid Level Indicator UHZ-10C00N1000
Magnetic Liquid Level Indicator UHC-AB
MAGNETIC LEVEL GAUGE VAC UHZ-618C17
Magnetic Liqid Level Meter UHZ-AB
Magnetic Level Indicator UHZ-10007B
Magnetic Liquid Level Indicator UHZ-519C
Magnetic Liqid Level Indicator UHZ-10C00N4000


  • Previous:
  • Next:

  • Post time: May-30-2023