page_banner

Installation Guide and Precautions for KCB-55 Gear Oil Pump

Installation Guide and Precautions for KCB-55 Gear Oil Pump

As an efficient and reliable liquid transmission equipment, ensuring the correctness of the KCB-55 gear oil pump during installation is crucial for ensuring the long-term stable operation of the pump. The following are some key installation precautions aimed at helping users successfully complete installation and maintain optimal pump performance.

gear oil pump GPA2-16-E-20-R6.3 (5)

Before starting installation, the primary task is to conduct a comprehensive inspection of the pump. This includes confirming whether the motor has been affected by moisture during transportation, checking whether there is any damage to the dust cover at the inlet and outlet of the pump, to prevent external dirt from entering the pump chamber. Any potential damage should be repaired in a timely manner to avoid adverse effects on the efficiency and lifespan of the pump.

 

The KCB-55 oil pump should be arranged as close as possible to the oil pool to reduce the length of the oil suction pipeline and improve the oil suction efficiency. All pipeline connection points should ensure sealing to avoid air infiltration or liquid leakage, as both will directly affect the suction capacity of the pump.

EH oil main pump PVH074R01AB (1)

To prevent particulate impurities from entering the pump, a metal filter should be installed at the suction port of the pump. It is recommended to have a filtration accuracy of 30 mesh/inch and a filtration area at least three times the cross-sectional area of the oil inlet pipe to ensure sufficient filtration effect and smooth operation of the pump.

 

In order to monitor the working condition of the KCB-55 gear oil pump in real time, it is recommended to install vacuum gauges and pressure gauges separately on the inlet and outlet pipelines. These instruments can help operators to timely understand the operating status of the pump, making it easy to adjust and maintain.

 

When facing special working conditions such as deep oil pools, long oil suction pipelines, or high medium viscosity, additional measures need to be taken. For example, the suction resistance can be reduced by increasing the diameter of the oil inlet pipe, or a bottom valve can be installed on a long-distance suction pipe to prevent liquid backflow when the pump stops running, ensuring smooth suction during the next startup.

Oil Transfer Gear Pump 2CY-459-1A (3)

The installation of KCB-55 gear oil pump is a meticulous and strictly compliant process. By carefully implementing the above steps, not only can the normal start-up and efficient operation of the pump be ensured, but its service life can also be significantly extended, providing reliable support for enterprise production.

 

Yoyik can offer many spare parts for power plants as below:
BLADDER NXQ-AB-40 /20-LY
GREASE DISTRIBUTOR QJDF4-KM-3
Cooling fan YB3-250M-2
bellows globe valve core WJ50F1.6P.03
Solenoid valve 4WE6D62/EG110N9K4/V
Bladder NXQA-25L
DOUBLE ENTRY IMPELLER with IMPELLER SLEEVE HZB200-430-01-03+HZB200-430-01-04
Filter Replacement Kit for Moog G761 servo B2555RK201K001
Unloading valve WJXH.9330A
solenoid valve 22FDA-K2T-W220R-20/LV
Skeleton oil seal 589332
Shaft sleeve of seal oil vacuum pump reducer 317090HA
AST/OPC solenoid valve coil 300AA00126A
Minor Repair Kit for Three-Piece/Bolted Ball Valve Size : 1/2″, Pressure rating : 2000WOG (PN130) Welding End : BW, Items : #5, #6, #7, #8
Screw pump HSNH440-46
AST/OPC solenoid valve coil 300AA00086A
stainless steel globe throttle check valve (welded) LJC100-1.6P
Mechanical Stop Electromagnet DF2025
Globe valve WJ41B4.0P

 


  • Previous:
  • Next:

  • Post time: May-24-2024