page_banner

NUGNET diatomaceous earth filter element 30-150-207 has arrived

NUGNET diatomaceous earth filter element 30-150-207 has arrived

After two months, NUGENT's latest batch of filter elements in 2022 finally arrived.
The diatomite filter 30-150-270 is used in the fire-resistant oil regeneration device system of power plants. It is used in conjunction with the cellulose filter element, which can comprehensively improve the oil quality of the anti-fuel oil system and keep the acid value of the EH oil system within the normal range. .
DONGFANG YOYIK has established a long-term and stable cooperative relationship with NUGENT and is the company's only agent in China.
Our company keeps a large number of NUGENT filter cartridges in stock, and we look forward to your consultation.

The new anti-fuel acidity index is 0.03 (mgKOH/g). When the acidity index exceeds 0.1, it means that the acidity is too high. Within one month after the unit is put into operation, the regeneration device should run continuously for eight hours a week. After one month, it should be According to the test results of EH oil, it is decided whether it needs to be put into operation. In the normal operation of the EH system, the working oil temperature is 43.3 to 54.4 ℃, and cannot be higher than 57 ℃. If the oil temperature is too high, a series of changes will occur in the anti-fuel oil. After the acid value increases, it must be continuously input.

YOYIK, the general agent of NUGENT in China, will tell you: the regeneration device consists of two filter cartridges, one with diatomaceous earth filter element and the other with corrugated cellulose filter element, running in series, the former is responsible for reducing the acid in EH oil value, the latter removes diatomaceous earth and other particulate impurities in EH oil. The capacity of a diatomite filter element to absorb acid is about 0.03 kg, and the diatomite filter element in the regeneration device can effectively reduce the acidity of the fire-resistant oil. When the acidity of the fire-resistant oil is close to 0.1, the acidity will drop rapidly. When the acidity of the fire-resistant oil exceeds 0.3, it is difficult for a group of regeneration devices to reduce the acidity, and an external purification device can be selected. When the acidity of the fire-resistant oil exceeds 0.5, it cannot run and needs to be changed.

NUGNET diatomaceous earth filter element 30-150-207 has arrived (1)
NUGNET diatomaceous earth filter element 30-150-207 has arrived (1)
NUGNET diatomaceous earth filter element 30-150-207 has arrived (2)
NUGNET diatomaceous earth filter element 30-150-207 has arrived (2)

  • Previous:
  • Next:

  • Post time: Jun-11-2022