Home
Products
Sensor
Speed Sensor
Lvdt Sensor
Press Sensor
Eddy Current Sensor
Other Sensor
Filter
Oil Filter
Air Filter
Water Filter
Pump
Oil Pump
Water Pump
Other Pump
Pump Spare Parts
Valve
Globe Valve
Solenoid Valve
Servo Valve
Float Valve
Differential Pressure Valve
Other Valve
Automatic Control
cards & module
Meter
Transmitter
PLC
other
Power Generation Equipment Parts
Steam Turbine Parts
Generator Parts
Boiler Parts
Auxiliary Parts
Insulating Material
Insulating Adhesive & Paint
Insulation Pressed Parts
Insulating Material
Sealing Material
Sealant
Sealing Grease
Sealing Strip
Seal Ring
Others
Bearing
Bearing
Accumulators And Bladders
Accumulators Bladders And Spare Parts
News
About Us
Company Profile
History
Support
Supply Chain
Service
Contact Us
FAQs
/
English
News
Importance of The End Cover to the Hydraulic Oil Filter WU-100×100-J
by Yoyik Kara on 23-08-04
The hydraulic oil filter element WU-100×100-J is a commonly used industrial coarse filter element. As a filter element with high oil flow capacity and low resistance, the quality of the end cover of the WU-100×100-J filter element is important for its filtration effectiveness. 1. Seal...
Read more
How Does the Actuator Filter ZTJ.00.07 Stay Stable in High Temperature EH Oil?
by Yoyik Kara on 23-08-04
The EH oil actuator filter ZTJ.00.07 has good temperature stability. It can maintain high filtration efficiency and operational stability in high-temperature environments, ensuring that the system is not affected by particles and pollutants in high-temperature environments. In high-temperature e...
Read more
The Speciality of Steam Turbine EH Oil Filter AP1E102-01D10V/-W
by Yoyik Kara on 23-08-04
Phosphate ester fire-resistant oil is a special hydraulic oil with some significant differences compared to regular hydraulic oil. Therefore, the oil filters used for phosphate ester anti-flammable oil and regular hydraulic oil also have some differences. As a manufacturer of high-quality fire-re...
Read more
Features of Stainless Steel Back-Flushing Filter Cartridge KLS-125T/60
by Yoyik Kara on 23-08-02
The stainless steel back flushing filter element KLS-125T/60 has a large filtration area and a long lifespan. It can filter a large amount of impurities and particles while being reusable. This makes it widely used in industrial applications that require long continuous operation or efficient fil...
Read more
Possible Reasons of Oil Pump Suction Filter JCAJ007 Clogging
by Yoyik Kara on 23-08-02
The condition of the hydraulic oil in a hydraulic system greatly affects the operation of the oil pump. It is necessary to install an oil pump suction filter JCAJ007 in the pump. However, the filter located at the pump inlet often gets clogged. Yoyik would like to introduce some possible reasons ...
Read more
Application of Differential Pressure Sensor RC861CZ090HYM in Industry
by Yoyik Kara on 23-08-02
The pressure switch RC861CZ090HYM is a common pressure indicator that operates by detecting the pressure difference between the inlet and outlet of the filter element. It has an adjustable pressure range that can be set according to specific requirements. Furthermore, it utilizes a threaded conne...
Read more
What Can the Position Sensor TDZ-1 Do On Steam Turbine Actuator?
by Yoyik Kara on 23-08-02
The linear displacement sensor TDZ-1 can be used to monitor the displacement and vibration of various key components in steam turbines to ensure their normal operation and safety performance. One of its main applications is in the actuator of the steam turbine, to monitor the valve position and v...
Read more
Function of TSI Card 3500/53 In Measuring Rotation Speed
by Yoyik Kara on 23-08-02
The TSI Card 3500/53 can be used to form a 2-out-of-2 or 3-out-of-3 voting system. It is a highly reliable and fast-responding redundant overspeed protection system specifically designed for mechanical applications. Each channel of the 3500/53 TSI Card can be programmed using the 3500 configurat...
Read more
Trouble-Shooting of AST Solenoid Valve ZD.02.004 in Steam Turbine
by Yoyik Kara on 23-08-01
The AST solenoid valves working in the high-temperature and high-pressure environment of the steam turbine may have some common faults, such as the solenoid valve does not act, blocking, etc. As a supplier of steam turbine spare parts, Yoyik summarized some solutions to common faults of AST solen...
Read more
Two Indication Modes of the Absolute Expansion Sensor TD-2 0-80mm
by Yoyik Kara on 23-07-31
During the starting of a steam turbine, the turbine casing expands gradually, and during shutdown, the metal temperatures of various parts of the turbine decrease, causing the casing to contract gradually and reduce in expansion. The absolute expansion sensor TD-2 0-80mm is used to detect the exp...
Read more
Advantages of Using Armored Cables for DET300A Displacement Sensor LVDT
by Yoyik Kara on 23-07-31
Our displacement sensor LVDT DET300A is equipped with armored cables. Although armored cables have higher costs compared to ordinary cables, they have more advantages. They have higher pressure resistance, reliable sealing, and can prevent water immersion. The use of armored cables for displacem...
Read more
The Common Faults of AST Solenoid Valve ZD.02.009
by Yoyik Kara on 23-07-31
The AST solenoid valve ZD.02.009 is an important component for emergency shutdown of the steam turbine. Therefore, regular maintenance and monitoring of the solenoid valve are necessary in daily use to promptly address any faults and ensure the normal operation of the system. Yoyik has summarize...
Read more
<<