Home
Products
Sensor
Speed Sensor
Lvdt Sensor
Press Sensor
Eddy Current Sensor
Other Sensor
Filter
Oil Filter
Air Filter
Water Filter
Pump
Oil Pump
Water Pump
Other Pump
Pump Spare Parts
Valve
Globe Valve
Solenoid Valve
Servo Valve
Float Valve
Differential Pressure Valve
Other Valve
Automatic Control
cards & module
Meter
Transmitter
PLC
other
Power Generation Equipment Parts
Steam Turbine Parts
Generator Parts
Boiler Parts
Auxiliary Parts
Insulating Material
Insulating Adhesive & Paint
Insulation Pressed Parts
Insulating Material
Sealing Material
Sealant
Sealing Grease
Sealing Strip
Seal Ring
Others
Bearing
Bearing
Accumulators And Bladders
Accumulators Bladders And Spare Parts
News
About Us
Company Profile
History
Support
Supply Chain
Service
Contact Us
FAQs
/
English
News
How to Know the Bladder of Accumulator NXQ-A1.6/20-H-HT Needs to Be Changed?
by Kara on 23-07-19
For a bladder type accumulator NXQ-A1.6/20-H-HT, the bladder is the most important component and is also the most commonly damaged one. Therefore, users need to regularly check the condition of the bladder to know whether the bladder of the accumulator should be replaced, in order to avoid hydrau...
Read more
Reasons of The Jam Faults to Servo Valve ZD.01.003
by Kara on 23-07-19
As a commonly used hydraulic component, servo valve ZD.01.003 may get stuck due to various reasons. Yoyik summarized some common causes of servo valve jamming as follows. 1. Oil Contamination: Internal components of the servo valve ZD.01.003, such as the spool and valve seat, may become blocked...
Read more
Method of Replacing Servo Valve J761-003A Seal Kits
by Kara on 23-07-19
The spare parts of servo valve J761-003A may need to be replaced frequently during long-term operation. For example, when the seal is used for a long time or contaminated, it may wear or age, leading to leakage of the servo valve and requiring timely replacement. Replacing servo valve seals usual...
Read more
How Does the Servo Valve DH.00.176 Control The Steam Turbine?
by Kara on 23-07-19
The servo valve DH.00.176 achieves accurate control of steam flow by monitoring and adjusting the opening of the main steam valve, thereby effectively controlling the load of the steam turbine. In this way, the steam turbine can flexibly adapt to changes in load demand and maintain stable operati...
Read more
What to Do If The EH Oil Circulating Pump 02-125801-3 Is Blocked?
by Kara on 23-07-19
Mechanical jamming of oil pumps is a common fault situation. When mechanical blockage occurs in the oil circulating pump 02-125801-3, there may be these reasons: 1) The EH oil becomes dirty, and impurities in the oil enter the pump, causing blockage. 2) Damaged bearings on the motor or ...
Read more
Function of Vacuum Pump 30SPEN for Generator Sealing Oil
by Kara on 23-07-19
The generator sealing oil system is one of the important systems used to maintain the sealing performance of the oil seal rings of the generator. During the operation of the generator, seal rings are required internally to ensure sealing between rotating components (such as bearings) and stationa...
Read more
Precautions for Using OPC Solenoid Valve Z2804076
by Kara on 23-07-19
The OPC solenoid valve Z2804076 is a normally closed solenoid valve used in the DEH monitoring and protection system of large steam turbine units. When using this type of OPC solenoid valve, the following precautions should be taken to ensure its normal operation and avoid safety accidents. The...
Read more
Features of OPC Solenoid Valve AM-501-1-0149 for Steam Turbine
by Kara on 23-07-19
The purpose of the steam turbine OPC control system is to prevent overspeed on the steam turbine generator set and help improve the stability of the power system. The solenoid valve AM-501-1-0149 is a commonly used solenoid valve in OPC systems. It has good sealing performance, long service life,...
Read more
What Does the Float Valve BYF-40 Do for Generator Sealing Oil Tank?
by Kara on 23-07-19
Floating ball valve BYF-40 is a fluid control valve commonly used in power plants to seal oil tanks. The valve is controlled to open and close by the buoyancy of the floating ball. It has the characteristics of simplicity, reliability, high sensitivity, strong corrosion resistance, and convenient...
Read more
Difference Between Globe Throttle Check Valve LJC50-1.6P and Globe Valves
by Kara on 23-07-17
The globe throttle check valve LJC50-1.6P is a spare part of the hydrogen cooling system of the generator in the thermal power plant. Its function is to control the cooling water flow of the generator and avoid water backflow, so as to prevent the generator set from being damaged by water hammer ...
Read more
Attentions of Installing Bladder Accumulator NXQ-A-25/31.5
by Kara on 23-07-17
A bladder type accumulator is a pressure vessel that needs to be installed according to specifications to avoid errors during installation and ensure optimal performance and safety during use. Yoyik often answers customers’ questions about the installation of NXQ series bladder accumulators...
Read more
Why Does Stator Cooling Water Use the Centrifugal Pump YCZ50-250B?
by Kara on 23-07-17
In the generator stator cooling system, the YCZ50-250C centrifugal pump is used to circulate the cooling water, taking away the heat generated during the operation of the generator stator winding, and maintaining the temperature of the stator winding within the allowable range. This pump adopts a...