  • Function of Air Breather BR110+EF4-50 (UN1 1/2) in Steam Turbine EH Oil System

    The EH oil system is a lubrication system used in steam turbines to provide lubricating oil to critical rotating components, such as bearings and gears, to ensure their normal operation. For the EH oil system oil tank of the steam turbine, the function of the air filter is to filter water and par...
    Read more
  • Advantage of Stainless Steel Perforated Filter KLS-50U/200

    The filter element KLS-50U/200 is a stainless steel perforated filter. In thermal power station, it is used in the generator stator cooling water system, installed in the make-up water filter, near the make-up water point or water inlet. Its design purpose is to capture and filter impurities such...
    Read more
  • Introducing the Repetitive Accuracy of LVDT Transducer 8000TD

    The repeatability accuracy of LVDT displacement sensors refers to the stability and consistency of the measurement results output by the sensor during repeated displacement measurements. Simply put, it measures how consistent and reliable the sensor can provide in multiple repeated measurements. ...
    Read more
  • What Is the Dynamic Characteristics of Position Sensor 6000TDGN

    The dynamic characteristics of LVDT displacement sensors refer to their responsiveness and performance under changing displacement conditions. Taking the 6000TDGN sensor as an example, we will introduce the characteristics and advantages of LVDT displacement sensors with good dynamic performance....
    Read more
  • Factors Affecting the Sensitivity of LVDT Sensor 5000TDGN

    The LVDT sensor 5000TDGN is a high-precision sensor mainly used to measure the small displacement of steam turbine valves. In order to ensure the measurement accuracy and sensitivity of the sensor, it is necessary to pay attention to several factors when using them, which can affect the accuracy ...
    Read more
  • Impact of Incorrect Installation on Displacement Sensor TD-1-50

    We know that the LVDT displacement sensor TD-1-50 is an important turbine control component. Its structure is simple, easy to use, and it can reliably monitor and protect the stroke and valve position of the turbine oil motor. However, if the installation of LVDT displacement sensor TD-1-50 is in...
    Read more
  • What Can Cause Display Errors of Speed Monitor RZQW-03A

    Rotation speed is an important operational monitoring parameter for steam turbine units. RZQW-03A tachometer is an instrument specially used to monitor the speed of steam turbine and the status of emergency governor. It displays the speed value of the turbine through a display panel. But when the...
    Read more
  • Installation Precautions of LVDT Displacement Sensor TD-1100S

    When installing LVDT displacement sensor TD-1100S on steam turbine, there are some precautions need to follow: Installation location selection: Select an appropriate installation location to ensure that the TD-1100S sensor can make normal contact or measure the displacement of the target object...
    Read more
  • The Working Method of Case Expansion Transducer TD-2 0-35mm

    The phenomenon of thermal expansion of the steam turbine casing is called “cylinder expansion”. The thermal expansion sensor TD-2 is used to monitor the varying degrees of thermal expansion of steam turbine casing during temperature changes or operating conditions during startup and s...
    Read more
  • How Does Temperature Affect theDisplacement Sensor TDZ-1-02?

    The working temperature range of LVDT displacement sensor TDZ-1-02 is usually -40 ℃ to 150 ℃. Within this range, the sensor can operate normally and provide accurate displacement measurement. However, if the ambient temperature exceeds the operating temperature range of the TDZ-1-02 sensor, it wi...
    Read more
  • LVDT Sensor TDZ-1B-02 for Small Displacement Range Measuring

    The stroke displacement of the turbine actuator is driven by internal hydraulic pressure. When hydraulic or pneumatic pressure acts on components such as pistons or valves, they will force them to move linearly, resulting in stroke displacement. The stroke displacement of a steam turbine is usual...
    Read more
  • What is the Air Pipe Bellows GJCFB-15 for Boiler APH

    Due to the large amount of coal ash and corrosive gases in the working environment of the GJCT series gap measurement device, it is necessary to seal the gap probes, transmitters, etc. All pipelines and connections need to be sealed to prevent air leakage and ash emission. This can effectively ex...