page_banner

Operating Procedure for Replacing Oil Filter Element 1300R050W/HC/-B1H/AE-D

Operating Procedure for Replacing Oil Filter Element 1300R050W/HC/-B1H/AE-D

For industrial hydraulic equipment, regular replacement of filter elements is a key link to ensure system cleanliness, improve equipment stability and extend service life. The oil filter element 1300R050W/HC/-B1H/AE-D is a common high-efficiency filter element widely used in hydraulic or lubrication systems. Its replacement process needs to strictly follow safety regulations and professional operating procedures. The following is a set of detailed standard operating procedure guidelines to guide technicians to complete filter element replacement safely and efficiently.
oil pump suction filter C9209014 (4)

1. Preparation phase

  • Safety confirmation: Ensure that the working area is clean and ventilated, and wear personal protective equipment, including safety helmets, protective glasses, oil-proof gloves and protective clothing.
  • Tool and spare parts preparation: Prepare new filter element 1300R050W/HC/-B1H/AE-D, wrench, sealing ring, detergent, oil pan, oil absorbing paper, marking pen, etc.
  • System isolation: Close the inlet and outlet valves of the filter element circuit, drain the system pressure, and ensure the safety of the operation. If necessary, use a lock to lock the valve to prevent misoperation.

 

2. Draining oil and pressure relief

  • Draining old oil: Open the drain valve or drain port under the filter element, use the oil pan to collect the old oil, and pay attention to environmental protection.
  • Confirming no pressure: Check again that the system pressure has been completely released to avoid oil splashing during the disassembly process.

diatomite filter ZS.1100B-002 (3)

3. Filter element removal

  • Marking and recording: Mark the replacement date on the old filter element and record the filter element condition, such as appearance damage, degree of contamination, etc., to provide a basis for subsequent analysis.
  • Removing the filter element: Use appropriate tools to gently loosen the filter housing fixing bolts and carefully remove the old filter element to avoid damaging the housing or causing oil leakage.

 

4. Cleaning and inspection

  • Cleaning the filter housing: Use detergent and oil-absorbing paper to thoroughly clean the inside and outside of the filter housing and check for wear or damage.
  • Replacing the seal ring: Replace the seal ring inside and outside the filter housing according to the manufacturer’s recommendations to ensure sealing performance.

control valve actuator inlet working filter AP3E302-01D10V-W (4)

5. Install new filter element

  • Check new filter element: Confirm that the new filter element 1300R050W/HC/-B1H/AE-D model is correct, check that the packaging is intact, and avoid using damaged or expired filter elements.
  • Install new filter element: Place the new filter element smoothly into the filter housing, ensure the installation direction is correct, and avoid damaging the filter paper layer.
  • Tighten and seal: Tighten the filter housing bolts evenly, use a torque wrench to tighten according to the specified torque value, and finally check the sealing.

 

6. System recovery and inspection

  • Open the valve: Slowly open the filter inlet and outlet valves to check for leaks.
  • System exhaust: Exhaust according to the system operating procedures to ensure that the oil path is unobstructed.
  • Oil level check: Add new oil to the specified oil level, check the oil quality, and replace some of the oil in the system if necessary.

 

7. Startup and monitoring

  • System startup: Start the system step by step according to the equipment operating procedures, pay attention to the pressure gauge and thermometer readings to ensure that everything is normal.
  • Subsequent monitoring: Closely monitor the working status of the filter element, including pressure difference changes, in the initial operation to ensure stable operation of the system after replacement.

 

Following the above standard operating procedures can not only ensure the smooth replacement of filter element 1300R050W/HC/-B1H/AE-D, but also improve the safety and reliability of system operation and extend the service life of the equipment.


Yoyik supply multiple types of filters used in steam turbine and generator system:
gearbox oil filter DP201EA03V/-W EH oil filter controls the BFPT Stop valve
hydraulic filter cross reference chart AP3E302-02D10V/-W MSV\CV\RCV actuator working filter
oil filter crusher FAX 400*10 lube oil and filter change
industrial filtration companies HTGY300B.6 EH oil return filter element
oil filter look up SFX-660X30 Oil Filter
stainless steel powder sintered filter FRD.5TK6.8G3 double cartridge filter
turbine filter SYLA-2
hydraulic filter system DZ903EA10V/-W regeneration Cellulose filter
cross reference hydraulic filter SLAF-10HT
uni air filter oil HTGY300B.4 oil filter precision filter
filter pressure hydraulic QF6803GA20H1.5C cellulose filter
stainless steel cartridge JCAJ007 EH oil main pump discharge filter
stainless steel 5 micron filter LH0160D020BN/HC BFP double cartridge filter
best water filtration WFF-125-1 filter
filter assy oil AD1E101-1D03V/-WF FILTER ELEMENT OIL
1 micron stainless steel filter 21FC-5121-160*400-25 double cartridge filter
oil and filter change cost OF3-08-3R turbine filter
water filtration companies near me KLS-1001 generator stator cooling water wire filter
lube oil auto backwash filter XYGN8536HP1046-V regeneration resin filter
20 string wound filter WFF-150*1 Water Filter element


  • Previous:
  • Next:

  • Post time: Jun-12-2024