As a widely used product, the fault detection and diagnosis of the solenoid valve 1-24-DC-16 24102-12-4R-B13 can not only improve the availability and reliability of the equipment, but also effectively prevent production interruptions caused by solenoid valve failure.
1-24-DC-16 24102-12-4R-B13 is a DC 24V powered solenoid valve designed to control the flow of various media (such as air, water, oil, etc.). Common faults of this solenoid valve include but are not limited to solenoid failure, seal wear, medium blockage, coil overheating, etc. The following are common methods for fault detection and diagnosis of solenoid valves.
1. Visual inspection and auscultation: First, perform a basic appearance inspection to check if there is obvious physical damage, leaks or foreign matter blockage. At the same time, by auscultating the sound of the solenoid valve action, determine whether there is abnormal noise, such as the clicking sound of the solenoid not being attracted smoothly.
2. Voltage and current measurement: Use a multimeter to measure whether the voltage across the solenoid coil is the nominal value (24V DC in this case) and whether the current when the coil is working is within the normal range. Abnormal voltage or current values may indicate a power supply problem or coil failure.
3. Resistance test: Measure the resistance value of the solenoid coil in the power-off state and compare it with the standard value provided by the manufacturer. Significant deviations may mean that the coil is short-circuited or open-circuited internally.
4. Pressure test: Use a pressure gauge to monitor the pressure changes at the inlet and outlet of the solenoid valve to evaluate the efficiency of valve opening and closing, and whether there is pressure loss due to poor sealing.
5. Temperature monitoring: Check the coil temperature regularly. Overheating may be a sign of excessive coil load or poor heat dissipation.
In order to effectively implement the above fault detection and diagnosis strategies, it is recommended to:
- Establish a regular maintenance plan: According to the operating conditions of the equipment, develop a detailed inspection and maintenance schedule to preventively replace wearing parts.
- Train operation and maintenance personnel: Ensure that team members are familiar with the structure, working principle and troubleshooting techniques of the solenoid valve.
- Adopt modern monitoring tools: Consider investing in smart diagnostic systems or sensors, especially for solenoid valves in critical processes, to achieve early warning of failures.
- Spare parts management: Maintain a stock of necessary spare parts, including coils, seals, etc., to cope with unexpected failures and shorten maintenance response time.
Yoyik offers various types of valves and pumps and its spare parts for power plants:
OPC solenoid valve HQ16.17Z
Power plant shut-off valves WJ50F3.2P
Blet 1400*7330
Bellows valves WJ20F2.5P
Valve D661-4043
Reset solenoid valve MFZ3-90YC
accumulator pressure testing kit NXQA.25/31.5
Bellows valves KHWJ80F1.6P
Internal Poppet Valve of Soot Blowerr O0000373
pump coupling & cushion PVH098R01AJ30A250000001001AB010A
globe valve control 80FWJ1.6P
Gas turbine seal oil vacuum pump reducer M01225.OBMCC1D1.5A
Pump driven screw ACG060N7NVBP
Drain Valve M-3SEW6U37/420MG24N9K4/V
main stop valve KHWJ20F-1.6P
PTEF Solenoid Valve 1/4″ NPT-, Ex-Proof with Viton Seal, for sulfuric Acid 98.9%
VALVE 73218BN4UNLVNOC111C2
Spider coupling rotex 24 FD Fan
AST solenoid valve HQ16.18Z
solenoid valve J-220VDC-DN10-Y/20H/2AL
Post time: Jul-01-2024