Solenoid Valve J-110VDC-DN6-PK/30B/102A: Effect of Switching Frequency on Service Life

Solenoid Valve J-110VDC-DN6-PK/30B/102A: Effect of Switching Frequency on Service Life

The working principle of the solenoid valve J-110VDC-DN6-PK/30B/102A is to control the movement of the valve core through electromagnetic force, thereby switching the direction of the oil circuit. The switching frequency of the valve refers to the number of times the valve completes the switching action per unit time. The higher the frequency, the busier the valve is, which is directly related to the wear and service life of the valve.

solenoid valve J-110VDC (2)

The switching frequency has a great impact on the life of the solenoid valve J-110VDC-DN6-PK/30B/102A. When the frequency is high, the electromagnetic coil and the valve core frequently move, which will cause the following problems:

  • Wear of the electromagnetic coil: Under high-frequency switching, the electromagnetic coil is prone to heat accumulation, resulting in aging of the coil and damage to the insulation layer, which ultimately affects the service life of the coil.
  • Wear of the valve core and valve seat: Frequent switching actions make the contact between the valve core and the valve seat frequent, resulting in increased wear and reduced sealing performance.
  • Material fatigue: The spring and valve core and other components inside the valve are prone to fatigue under high-frequency switching, which reduces the strength and affects the stability of the valve.
  • Controlling the switching frequency: the key to extending the life

TEST SOLENOID VALVE MFZ3-90YC (2)

To extend the service life of the solenoid valve J-110VDC-DN6-PK/30B/102A, controlling the switching frequency is the key. Here are some methods:

  • Optimize the control system: By optimizing the control logic, reduce unnecessary switching actions, such as setting a reasonable delay or logical judgment to avoid frequent switching of the valve.
  • Reasonable setting of parameters: According to the actual working conditions, reasonably set the working parameters of the valve, such as adjusting the switching threshold to reduce the ineffective action of the valve.
  • Regular maintenance: Regularly check the resistance and insulation performance of the electromagnetic coil to ensure that the coil is in good condition. Check the wear of the valve core and valve seat, and replace the worn parts if necessary.
  • Select high-quality materials: Choose wear-resistant and fatigue-resistant materials to make valve components to improve the durability of the valve.
  • Add buffer devices: Add buffer devices inside the valve to reduce the impact force when the valve core moves and reduce wear.

solenoid valve J-110VDC (1)

In actual work, you can learn how to control the switching frequency through some cases. For example, a power plant found that the life of the electromagnetic reversing valve J-110VDC-DN6-PK/30B/102A was short during operation. After analysis, it was found that it was because of unnecessary frequent switching actions in the control system. So, they optimized the control logic, increased the delay setting, and reduced the number of valve switching times. As a result, the life of the valve was significantly extended.

 

The switching frequency of the solenoid directional valve J-110VDC-DN6-PK/30B/102A directly affects the life of the valve. For engineers, understanding the impact of the switching frequency on the valve and mastering the method of controlling the switching frequency are the key to ensuring the long-term stable operation of the valve.
Yoyik offers various types of valves and pumps and its spare parts for power plants:
gearbox manufacturer M01225
valve CBH A2889B
One-way valve 126*48mm
Hydrogen side DC oil pump HSNH440Q2-46NZ
Ion exchanger pressure gauge primary valve WJ15F3.2P
piston pump operation PVH098R01AD30A250000002001AB010A
safety valve DGMC-3-PT-FW-30
Rubber Bladder for ST Low Pressure Accumulator NXQ 10/10-L-E
Isolation valve F3DG5S2-062A-220DC50-DFZK-V/B08
Hydrogen shut-off valve WJ61W-16P
vacuum pump spares P-1761
sealing oil differential pressure valve KC50P-97
Lubricating oil pump bearing ALD320-20X2
Slide Gate Valve Spare Parts 200×200 PN1.0
SERVOVALVE HYDRAULIC SM4-40(40)151-80/40-10-H919H
water pump for condenser YCZ65-250B
Oil Pump Assy 186C1123G001
BLADDER FOR ACCUMULATOR A-10/31.5-L-EH
straight stop shut off valve KHWJ40F1.6
bladder accumulator working principle NXQ-A-1.6L/31.5-L-Y


  • Previous:
  • Next:

  • Post time: Jul-25-2024