page_banner

Stability and Repeatability of Solenoid Valve 22FDA-F5T-W110R-20L/P

Stability and Repeatability of Solenoid Valve 22FDA-F5T-W110R-20L/P

Solenoid valve 22FDA-F5T-W110R-20L/P is widely used in the test and control of steam turbines due to its excellent performance.

Solenoid valve 22FDA-F5T-W220R-20LBO (3)

The AST solenoid valve in the steam turbine ETS is powered closed during normal operation, preventing the automatic shutdown emergency shut-off of the anti-fuel oil channel on the mother pipe. In testing or real emergency situations, these solenoid valves will lose power and open, causing the oil pressure to drop, which will trigger all steam valves to close and shut down the steam turbine. The test solenoid valve 22FDA-F5T-W110R-20L/P can be used to simulate this emergency shutdown condition to verify the response and integrity of the ETS system.

 

The test solenoid valve 22FDA-F5T-W110R-20L/P can also be used to test the position feedback and response time of the control valve to ensure that the valve can accurately respond to instructions under various operating conditions. When conducting online tests, the oil circuit path can be changed by operating the oil circuit switching valve, so that the test solenoid valve can be tested without affecting the normal operation of the steam turbine.

22FDA-F5T (1)

Stability refers to the ability of the solenoid valve to maintain its performance parameters unchanged after a long period of operation or a certain number of operations. Repeatability refers to the ability of the solenoid valve to repeatedly show consistent performance characteristics, such as response time, action accuracy, etc., under the same test conditions.

 

Factors affecting stability and repeatability:

  • Environmental conditions: Factors such as temperature, humidity, and vibration can affect the performance of the solenoid valve.
  • Power supply fluctuations: Voltage instability may affect the normal operation of the solenoid valve.
  • Wear and aging: Mechanical wear and material aging inside the solenoid valve will gradually affect its performance.
  • Cleanliness: The solenoid valve has extremely high requirements for the cleanliness of the medium, and impurities may hinder normal operation.

Solenoid valve 22FDA-F5T-W220R-20LBO (2)

By following strict test procedures and standards, combined with effective maintenance strategies, the stability and repeatability of the turbine test solenoid valve 22FDA-F5T-W110R-20L/P can be significantly improved to ensure its reliable operation in the turbine control system. This can not only improve the overall performance of the turbine, but also reduce unplanned downtime caused by solenoid valve failure, thereby improving economic benefits and operating efficiency.
Yoyik offers various types of valves and pumps and its spare parts for power plants:
Shaft bearing 2 Pcs /80DV PHV P19183E-00
globe valve 1 50FWJ1.6P
SOLENOID VALVE 5811220100
DEH solenoid valve G761-3033B
Electro-hydraulic direction valve 4WE10D50/EG220N9K4/V
Flow Control Servo Valve G631-3014B-5
vacuum pump rear end cap 30-WS
Bellows valves WJ50F-2.5P
SOLENOID VALVE GS021600V + CCP230M
oil pump types TCM589332-00G
level gauge BM26A/P/C/RRL/K1/MS15/MC/V/V
dual outlet stop valve WJ41B-40P
Accumulator air bladder DXNQ200
DDV servo valve MOOG72-1202-10
Gear Reducer Assly XLD-4
“O” type Seal ring HN 7445-75.5×3.55
accumulator unloading valve NXQ A-25/31.5-L-EH-S
solenoid 22FDA-F5T-W220R-20/LB0
Globe valve WJ10F-16F
solenoid valve HQ16.14Z


  • Previous:
  • Next:

  • Post time: Jul-03-2024