Accurate temperature monitoring is a key link to ensure the safety of industrial production equipment and optimize energy utilization. Among them, the thermal resistance WZPM2-08-78-M18-S, as a high-performance temperature sensor, plays an indispensable role in the temperature measurement points of power plants with its high precision, stability and reliability. Now we will explore the application of WZPM2-08-78-M18-S in power plants from the perspective of full life cycle management of selection, installation, commissioning, operation and maintenance.
I. Selection: Accurate matching, laying a solid foundation
Selection is the first step in the full life cycle management of thermal resistors, which is directly related to the subsequent use effect and maintenance cost. When selecting a power plant, the following key points need to be considered:
1. Measurement range and environmental adaptability: According to the temperature range of different parts of the power plant, select the WZPM2-08-78-M18-S model that can withstand extreme temperature changes. At the same time, consider its corrosion resistance, high pressure resistance and other characteristics to ensure long-term stable operation in harsh environments.
2. Accuracy and stability: WZPM2-08-78-M18-S is known for its high accuracy. When selecting, it is necessary to confirm whether its accuracy level meets the requirements of the power plant monitoring system to ensure that the temperature data is accurate.
3. Installation and connection method: According to the space limitations and convenience of the installation location, select appropriate installation accessories and connection methods, such as direct thread installation, flange installation or remote signal transmission through the transmitter.
II. Installation: Standardize operation to ensure accurate measurement
Correct installation is the basis for ensuring the performance of thermal resistors. When installing thermal resistance WZPM2-08-78-M18-S, pay attention to the following points:
1. Location selection: Ensure that the installation location can truly reflect the temperature of the measured medium, avoid local overheating or overcooling areas, and consider easy maintenance and replacement.
2. Installation depth: According to the thermal conductivity characteristics and flow rate of the measured medium, reasonably determine the insertion depth of the thermal resistance to ensure the representativeness of the measured value.
3. Sealing and insulation: Good sealing can prevent medium leakage and external interference, and insulation measures can effectively avoid electrical short circuits and ensure measurement safety.
4. Calibration and testing: After installation, perform the initial calibration to ensure that the output signal of the thermal resistance WZPM2-08-78-M18-S is consistent with the standard temperature source, providing a reliable benchmark for subsequent operation.
III. Debugging and operation: fine-tuning and continuous optimization
During the debugging phase, the thermal resistance WZPM2-08-78-M18-S needs to be carefully parameterized and system-adjusted to ensure seamless connection with the DCS or other monitoring systems. This includes:
1. Signal verification: By simulating temperature changes, verify the correctness of the thermal resistance output signal, adjust system parameters in time, and eliminate errors.
2. Alarm setting: According to the safety regulations of the power plant, reasonably set the temperature over-limit alarm threshold to ensure that abnormal situations can be discovered and handled in time.
3. Operation monitoring: Implement regular inspections, record the operation data of WZPM2-08-78-M18-S, analyze its change trend, and prevent potential failures.
IV. Maintenance and troubleshooting: prevention first, quick response
Maintenance is the key to extending the service life of thermal resistors and maintaining measurement accuracy. For thermal resistors WZPM2-08-78-M18-S, the following maintenance mechanisms should be established:
1. Regular cleaning: remove dust and corrosion on the surface, keep the thermal resistance sensing end clean, and improve measurement sensitivity.
2. Insulation resistance detection: Check the insulation resistance regularly to prevent insulation degradation caused by moisture or aging, which affects measurement accuracy.
3. Troubleshooting: When encountering measurement abnormalities, first check whether the connection lines and wiring terminals are loose or corroded, and replace the WZPM2-08-78-M18-S components if necessary.
4. Spare parts management: Maintain an appropriate amount of inventory to ensure that the thermal resistance can be quickly replaced when it is damaged to reduce downtime.
In the full life cycle management of WZPM2-08-78-M18-S thermal resistors in power plants, from precise selection to standardized installation, from fine commissioning to efficient operation and maintenance, every step is crucial. Through scientific management strategies and technical means, not only can the operating efficiency and safety of the power plant be effectively improved, but the service life of the thermal resistance can also be extended and the maintenance cost can be reduced.
When looking for high-quality, reliable thermal resistance, YOYIK is undoubtedly a choice worth considering. The company specializes in providing a variety of power equipment including steam turbine accessories, and has won wide acclaim for its high-quality products and services. For more information or inquiries, please contact the customer service below:
E-mail: sales@yoyik.com
Tel: +86-838-2226655
Whatsapp: +86-13618105229
Yoyik offers various types of spare parts for steam turbines, generators, boilers in power plants:
Voltage transducer WBV414S01
LANCE STICK TINY OIL XDZ-1-1935
PRESSURE TRANSMITTER TPS20-G2Z-F8
bolts heater 1.2311(4)-φ18X1000
PRESSURE TRANSDUCE TYPE CAREBAR T P31
Signal Converter GJCF-15-E
tachometer pickup sensor CS-1
Bolt electric heating rod ZJ-20-T7
EDI Digital Control Panel MS1000A-6A
OIL LEVEL INDICATOR YZF2-250TH
TACHO METER SZC-04FG
Analog synchronous meter MZ10
Sensor RTD 6uide Bearing Generator Pad L 16 85mm x Dia 12 9mm
PRESSURE GAUGE EN 837-3 KL 1.6
CPU board GD2511008
Pressure transmitter CY-I
THERMAL RESISTANCE SENSOR WZPM2-08-102.5-M18-S
GAUGE PRESSURE 45-1279-SS-04L
Analog Input Module HAI805
industrial pressure transmitter RC771BZ090H
Speed probe CSG0650501
Contactor A210-30
Valve JDQ-1-RL2675
Switch Disconnectors OT125FT3
Acuator Transmitter 5000TD
inductive position sensor inductive nbn3-f25f-e8-v1
probe GJCFB-15
TWO-STAGE REDUCER GT2161407
Absolute expansion sensor TD-2-25
LVDT GV valve. A157.33.01.31
Post time: Feb-27-2025