Trouble-Shooting of AST Solenoid Valve ZD.02.004 in Steam Turbine

Trouble-Shooting of AST Solenoid Valve ZD.02.004 in Steam Turbine

The AST solenoid valves working in the high-temperature and high-pressure environment of the steam turbine may have some common faults, such as the solenoid valve does not act, blocking, etc. As a supplier of steam turbine spare parts, Yoyik summarized some solutions to common faults of AST solenoid valve. We take the solenoid valve ZD.02.004 as an example to introduce the method to solve the solenoid valve fault.

AST Solenoid Valve ZD.02.004

  • 1. Valve blockage: clean and maintain regularly to remove impurities, dirt or deposits inside the solenoid valve. It can be cleaned with proper detergent or solvent, or the solenoid valve can be disassembled for thorough cleaning.
  • 2. Valve leakage: check the status of solenoid valve seals, and replace them in time if aging or damage is found. Ensure that the solenoid valve is correctly connected and installed, and the fastening bolts are appropriate to ensure the sealing performance.AST Solenoid Valve ZD.02.004
  • 3. Fail to act: check whether the piston or diaphragm of the solenoid valve is stuck or stuck. If any, clean, lubricate or replace parts to ensure that the solenoid valve returns to normal operation.
  • 4. Solenoid valve circuit fault: check whether the circuit connection of the solenoid valve is normal, and eliminate poor contact, short circuit, open circuit or other electrical problems. Repair or replace electrical components to ensure that the solenoid valve receives the correct control signal.
  • 5. Solenoid valve drive problem: check whether the drive equipment of the solenoid valve, such as electromagnet or solenoid coil, works normally. If problems are found, the drive equipment can be repaired or replaced to ensure that the solenoid valve can operate smoothly.

AST Solenoid Valve ZD.02.004

Yoyik offers various types of pumps and valves for industrial users such as power generation industry:
Solenoid Valve (AST) GS021600V
Solenoid Valve Block 300AA00086A
Proportional Hydraulic Solenoid Valve OPC G130519
Hydraulic Solenoid Valve Coil Z6206060
5 Way Solenoid Valve SV1-10V-C-0-00
Solenoid Coil 24vdc R900941174
Solenoid Hydraulic Directional Control Valve D1VW004CNJW91
DEH Quick-Close Valve MFB-2.5YC
Solenoid Valve 110v 300AA00126A 230VAC
Hydraulic Solenoid Valve Types CCS230M
12v Solenoid Coil TAT.5002253
220v Solenoid Coil CCS115M 14W 120VDC
Coil Vickers SV1-10V-CD-240AG
12v Dc Solenoid HY-FXF10.08V
2 Way Pneumatic Valve SV4-10V-0-0-220AG
Normally Open Valve Types MCSCJ230AG000010
4 2 Dc Valve DG4V-5-2NJ-M-U-H6-20
Normally Open Solenoid Valve Z2804070


  • Previous:
  • Next:

  • Post time: Aug-01-2023