Speaking of UHZ-519C magnetic level indicator, this is a practical device widely used in chemical, petroleum, pharmaceutical and other industries to detect the liquid level of liquid media in various towers, tanks, tanks and other containers. Due to its unique working principle and structural design, it can still maintain high reliability and stability in harsh industrial environments. However, even such a durable device requires regular cleaning and maintenance to ensure its long-term accurate and error-free operation.
The working principle of UHZ-519C magnetic level indicator is based on buoyancy and magnetic coupling effects. When the liquid level in the container changes, the float in the main pipe moves up and down, and the permanent magnet in the float is transmitted to the external magnetic flip column through magnetic coupling, driving it to flip, thereby displaying the height of the liquid level. However, over time, dust and dirt may accumulate on the surface of the equipment, especially equipment installed outdoors or in industrial environments, which is more susceptible to contamination. This not only affects the appearance, but more importantly, excessive dust accumulation may affect the normal flipping of the magnetic flip column, resulting in inaccurate readings.
UHZ-519C cleaning and maintenance recommendations
The cleaning frequency mainly depends on the working environment of the equipment. Generally speaking, if the device is installed in a relatively clean indoor environment, it only needs to be cleaned once a year; for devices installed outdoors or in heavily polluted industrial environments, it is recommended to clean them at least once a quarter to ensure that they work properly.
When cleaning the UHZ-519C magnetic level indicator, the following steps should be followed:
- Power off: First, make sure that the device has been disconnected from the power supply to avoid the risk of short circuit or electric shock during cleaning.
- Disassembly: Depending on the specific structure of the device, some parts, such as the housing cover or the flip column panel, may need to be removed to facilitate cleaning of the internal components.
- Cleaning: Use a clean, soft cloth, dip in an appropriate amount of clean water or a mild detergent, and gently wipe the surface of the device and the flip column panel. For stains that are difficult to remove, you can use a soft brush to gently scrub, but remember not to use a hard brush to avoid scratching the surface.
- Drying: After cleaning, use a dry cloth to wipe off the moisture and make sure that all parts are completely dry before reassembling.
- Inspection: Before reassembling, check that all parts are intact, especially the magnetic flip column and float, to ensure that there is no jamming.
- Assembly and testing: Reassemble the device in the reverse order of disassembly, and then perform a functional test to confirm that the magnetic column can flip normally and the liquid level indication is accurate.
In addition to cleaning, the UHZ-519C magnetic liquid level indicator also requires regular maintenance inspections, mainly including:
- Check the sealing: Check the sealing of the equipment at least once a year to ensure that there is no leakage, especially for equipment working under corrosive or high-pressure conditions.
- Check the magnetic components: Regularly check the magnetic strength of the magnetic column and float to ensure that its magnetism has not weakened, otherwise it may affect the accurate indication of the liquid level.
- Check the connectors: Check whether all connectors are tight. If they are loose, they should be tightened in time to avoid poor connections caused by vibration.
- Calibration: Depending on the frequency of use of the equipment and environmental conditions, calibration may be required at regular intervals to ensure the accuracy of the readings.
Although the UHZ-519C magnetic liquid level indicator is designed to be sturdy, it also requires regular cleaning and maintenance to maintain its optimal performance. The cleaning frequency should be determined according to the working environment. It is generally recommended to clean it at least once a year, and the number of cleanings should be appropriately increased for severely polluted environments. Maintenance inspections should be performed at least once a year, focusing on the sealing, the status of the magnetic components and the tightness of the connectors.
The above is a detailed introduction to the cleaning and maintenance of the UHZ-519C magnetic level indicator. Proper cleaning and maintenance can not only keep the equipment in good condition, but also effectively avoid production interruptions caused by equipment failure, save costs for the company and improve production efficiency. I hope this article can help you better understand and master the maintenance knowledge of the UHZ-519C magnetic level indicator.
Yoyik can offer many spare parts for power plants as below:
EDI Module Power Supply MS1000A
HP Actuator LVDT Position Sensor DET150A
Magnetic Spd Pickup Sensor Ht CS-1 D-065-05-01
Voltage control board LD26389
thermal resistance of air WZP2-221
MODULE KN831E
pressure switch RCA218RZ097Z
THERMOCOUPLE WRNK2
HEAVY DUTY NEMA LIMIT SWITCH 9007C
thermocouple with surface probe WRNK2-291
Control board HQ5.530.005
displacement position and proximity sensors TDZ-1
Pressure vacuum gauge (-0.1-0MPa)Diameter:150mm,Accuracy: 1.6/2.5 YZ-150
Reflective Paper A29466-1
NEPM meter MW
LVDT Displacement Sensor DEA-LVDT-200-6
Preamplifier 330780-50-00
Thermometer WSS 581W Dial 150mm
tank level measurement UHZ-510CLR
turck position sensor HL-3-50-15
Post time: Jul-12-2024