During the operation of the power plant, the control system, as the brain of the entire power generation process, is of vital importance for its stability and reliability. In order to ensure the continuous and stable operation of the power plant control system, it is essential to use high-quality power supply equipment. UPS power supply SURT10000UXICH has become an indispensable part of the power plant control system with its excellent performance and stability. However, during use, the following matters still need to be noted to ensure its optimal performance and extend its service life.
1. Selection of installation environment
The installation environment of UPS power supply SURT10000UXICH should avoid direct sunlight and maintain proper ventilation space to prevent the equipment from overheating. It is recommended to control the working environment temperature between 20℃~25℃, because excessive temperature will shorten the life of the battery. At the same time, the installation location should be away from dust and corrosive gases to reduce damage to the internal electronic components of the equipment.
2. Reasonable distribution of load
In the power plant control system, the load of UPS power supply SURT10000UXICH should be controlled within the rated output power range of 50%~60%, which is the best working method. Avoid overloading, because overloading may cause the inverter transistor to break down, thereby damaging the equipment. At the same time, it is not advisable to operate with excessive light load, because the battery discharge current is too small and may also cause the battery to fail.
3. Correct on-off sequence
When starting and shutting down the UPS power supply, the operation should be strictly carried out in the correct order. When turning on the machine, the UPS power supply should be turned on first, and then the loads should be turned on one by one. When shutting down, the loads should be turned off one by one, and then the UPS power supply should be turned off. This can avoid the voltage output fluctuation of the UPS power supply when the load suddenly increases or decreases, which may cause the equipment to fail to work properly.
4. Battery management and maintenance
The battery of the UPS power supply SURT10000UXICH is an important component and needs to be checked and maintained regularly. The voltage and capacity of the battery should be checked regularly, and unqualified batteries should be replaced in time. At the same time, the battery should be charged and discharged regularly to maintain the activity of the battery. In normal use, if there is no interruption of the city power supply, the battery should be charged and discharged with load every 3 to 6 months. After the discharge is completed, the UPS charging time should be no less than 10 hours.
5. Avoid frequent power on and off
Frequent power on and off can damage the UPS power supply, so it should be avoided as much as possible. When you need to turn off the UPS power supply, you should wait at least 30 seconds before turning it on to reduce the impact on the equipment.
6. Grounding treatment and protective measures
The UPS power supply SURT10000UXICH should be properly grounded to prevent the high voltage generated inside the equipment from causing harm to the human body. At the same time, necessary protective measures should be taken, such as installing lightning protection and surge protection devices to reduce the impact of external power abnormalities on the equipment.
7. Regular maintenance and inspection
In order to ensure the best performance of the UPS power supply SURT10000UXICH, it should be maintained and inspected regularly. Including observing the status of the working indicator light, dust removal, measuring the battery voltage, checking the operation of the fan, and detecting and adjusting the system parameters of the UPS. Through regular maintenance and inspection, problems can be discovered and solved in time to ensure the stable operation of the equipment.
In summary, the use of UPS power supply SURT10000UXICH in power plant control systems requires attention to many aspects, including the selection of installation environment, reasonable distribution of loads, correct power on/off sequence, battery management and maintenance, avoiding frequent power on/off, grounding treatment and protective measures, and regular maintenance and inspection, etc. Only by following these precautions can the best performance of UPS power supply SURT10000UXICH in power plant control systems be ensured and its service life be extended.
When looking for high-quality, reliable power supplys, YOYIK is undoubtedly a choice worth considering. The company specializes in providing a variety of power equipment including steam turbine accessories, and has won wide acclaim for its high-quality products and services. For more information or inquiries, please contact the customer service below:
E-mail: sales@yoyik.com
Tel: +86-838-2226655
Whatsapp: +86-13618105229