page_banner

Company News

  • How Does the Actuator Filter ZTJ.00.07 Stay Stable in High Temperature EH Oil?

    The EH oil actuator filter ZTJ.00.07 has good temperature stability. It can maintain high filtration efficiency and operational stability in high-temperature environments, ensuring that the system is not affected by particles and pollutants in high-temperature environments. In high-temperature e...
    Read more
  • The Speciality of Steam Turbine EH Oil Filter AP1E102-01D10V/-W

    Phosphate ester fire-resistant oil is a special hydraulic oil with some significant differences compared to regular hydraulic oil. Therefore, the oil filters used for phosphate ester anti-flammable oil and regular hydraulic oil also have some differences. As a manufacturer of high-quality fire-re...
    Read more
  • Features of Stainless Steel Back-Flushing Filter Cartridge KLS-125T/60

    The stainless steel back flushing filter element KLS-125T/60 has a large filtration area and a long lifespan. It can filter a large amount of impurities and particles while being reusable. This makes it widely used in industrial applications that require long continuous operation or efficient fil...
    Read more
  • Possible Reasons of Oil Pump Suction Filter JCAJ007 Clogging

    The condition of the hydraulic oil in a hydraulic system greatly affects the operation of the oil pump. It is necessary to install an oil pump suction filter JCAJ007 in the pump. However, the filter located at the pump inlet often gets clogged. Yoyik would like to introduce some possible reasons ...
    Read more
  • Application of Differential Pressure Sensor RC861CZ090HYM in Industry

    The pressure switch RC861CZ090HYM is a common pressure indicator that operates by detecting the pressure difference between the inlet and outlet of the filter element. It has an adjustable pressure range that can be set according to specific requirements. Furthermore, it utilizes a threaded conne...
    Read more
  • What Can the Position Sensor TDZ-1 Do On Steam Turbine Actuator?

    The linear displacement sensor TDZ-1 can be used to monitor the displacement and vibration of various key components in steam turbines to ensure their normal operation and safety performance. One of its main applications is in the actuator of the steam turbine, to monitor the valve position and v...
    Read more
  • Function of TSI Card 3500/53 In Measuring Rotation Speed

    The TSI Card 3500/53 can be used to form a 2-out-of-2 or 3-out-of-3 voting system. It is a highly reliable and fast-responding redundant overspeed protection system specifically designed for mechanical applications. Each channel of the 3500/53 TSI Card can be programmed using the 3500 configurat...
    Read more
  • Trouble-Shooting of AST Solenoid Valve ZD.02.004 in Steam Turbine

    The AST solenoid valves working in the high-temperature and high-pressure environment of the steam turbine may have some common faults, such as the solenoid valve does not act, blocking, etc. As a supplier of steam turbine spare parts, Yoyik summarized some solutions to common faults of AST solen...
    Read more
  • Two Indication Modes of the Absolute Expansion Sensor TD-2 0-80mm

    During the starting of a steam turbine, the turbine casing expands gradually, and during shutdown, the metal temperatures of various parts of the turbine decrease, causing the casing to contract gradually and reduce in expansion. The absolute expansion sensor TD-2 0-80mm is used to detect the exp...
    Read more
  • Advantages of Using Armored Cables for DET300A Displacement Sensor LVDT

    Our displacement sensor LVDT DET300A is equipped with armored cables. Although armored cables have higher costs compared to ordinary cables, they have more advantages. They have higher pressure resistance, reliable sealing, and can prevent water immersion. The use of armored cables for displacem...
    Read more
  • The Common Faults of AST Solenoid Valve ZD.02.009

    The AST solenoid valve ZD.02.009 is an important component for emergency shutdown of the steam turbine. Therefore, regular maintenance and monitoring of the solenoid valve are necessary in daily use to promptly address any faults and ensure the normal operation of the system. Yoyik has summarize...
    Read more
  • Reason of Setting Two Channels of AST Solenoid Valve AM-501-1-0148

    The AST in the steam turbine refers to Auto Stop Trip, which is the executor of the ETS system. There are four solenoid valves AM-501-1-0148 on it. When a certain parameter of the steam turbine reaches the trip value, it releases all DEH control oil pressure to safely stop the unit in emergency. ...
    Read more