page_banner

Products

  • EH Circulating Junction oil filter QTL-250

    EH Circulating Junction oil filter QTL-250

    The EH Circulating Junction oil filter QTL-250 is used at the inlet of the turbine fire resistant oil (EH oil) pump to filter the phosphate oil in the fire resistant oil system and maintain the cleanliness of the phosphate oil to meet on-site usage requirements. The main purpose is to remove metal powder and other mechanical impurities from the worn components of the fire-resistant fuel system. Clean oil can reduce equipment wear and prolong the service life of the equipment.
    Brand: YOYIK
  • Recycle pump washing oil filter DP1A401EA01V/-F

    Recycle pump washing oil filter DP1A401EA01V/-F

    The Recycle pump washing oil filter DP1A401EA01V/-F is installed on the return oil pipeline of the EH oil system, located in a position where the pollution level of the control system is very effective. It can filter out small impurities in the EH oil with high filtration accuracy and belongs to the fine filter element. The use of filter element DP1A401EA01V/-F can extend the service life of hydraulic equipment. The use of stainless steel material has good filtration performance, wear resistance, high temperature resistance, pressure resistance, and a longer service life.
    Brand: YOYIK
  • Industrial filtration Lube oil system Lube filter LY-15/25W

    Industrial filtration Lube oil system Lube filter LY-15/25W

    The Lube filter LY-15/25W is installed in the oil filter of the lubricating oil system, and the oil filter is installed at the outlet of the pump, made of stainless steel. The filter element LY-15/25W is used for filtering the lubricating oil of steam turbines and is an effective measure to ensure the quality of lubricating oil. To ensure the operation of the unit, two filters are configured, one for operation and one for backup.
  • Generator Stator Cooling Water Filter MSL-125

    Generator Stator Cooling Water Filter MSL-125

    The generator stator cooling water filter MSL-125 is a filter element installed in the stator cooling water system of a power plant. The filter element adopts a PP wire wound structure, and the polypropylene melt blown filter element is used as the main support skeleton inside, which has a large amount of dirt and circulation. The filter element has a honeycomb structure with sparse exterior and dense interior, which can effectively remove impurities such as suspended solids, rust, and particles in the fluid. The filter element is lightweight and easy to install and disassemble.
  • OPC solenoid valve 4WE6D62/EG220N9K4/V

    OPC solenoid valve 4WE6D62/EG220N9K4/V

    The solenoid valve 4WE6D62/EG220N9K4/V adopts advanced proportional control technology, which can achieve precise control of flow, direction, and pressure. It has advantages such as fast response speed, high accuracy, and strong reliability. Its main purpose is to control the flow, direction, and pressure of liquids in hydraulic systems, and is widely used in hydraulic systems in fields such as machinery, metallurgy, petrochemical, and light industry.
  • Main sealing oil pump HSND280-46N

    Main sealing oil pump HSND280-46N

    Main sealing oil pump HSND280-46N is a vertical installation oil pump with side inlet and side outlet. It is sealed with a skeleton oil seal and is mainly configured in the sealing oil system. After being pressurized by the main sealing oil pump, it is filtered through a filter screen, and then adjusted to a suitable pressure by a differential pressure regulating valve to enter the generator sealing pad. The return oil on the air side enters the air separation box, while the return oil on the hydrogen side enters the sealing oil return box and then flows into the float oil tank, and then relies on the pressure difference to flow into the air separation box. The unit is generally equipped with one for operation and the other for backup, both driven by AC motors.
  • Steam turbine servo valve PSSV-890-DF0056A

    Steam turbine servo valve PSSV-890-DF0056A

    The servo valve PSSV-890-DF0056A is mainly used for automation control in control systems. In addition to being used in the power plant industry, it is also widely used in other hydraulic control systems, such as machine tools, injection molding machines, metallurgical equipment, aerospace equipment, automobiles, ships, petroleum, chemical engineering, water conservancy, mining, and other fields. In addition, the servo valve PSSV-890-DF0056A can also be used for adjusting and controlling parameters such as flow, pressure, liquid level, and temperature in industrial automation control systems, as well as precise control and motion control in fields such as robots, stages, and display equipment.
  • EH oil main pump PVH098R01AD30A250000002001AB010A

    EH oil main pump PVH098R01AD30A250000002001AB010A

    The EH oil main pump PVH098R01AD30A250000002001AB010A is a high flow, high-performance pump designed by VICKERS, and is a member of the variable displacement direct axis piston pump. This pump includes the tested designs of other Vickers piston pumps. This pump is efficient, reliable, and has maximum flexibility in use with optional control methods. Before the initial start of the pump, fill the casing with the type of hydraulic fluid used through the highest oil drain port. The shell drain pipe must be directly connected to the oil tank and below the liquid level.
  • Vacuum pump rocker seal P-1764-1

    Vacuum pump rocker seal P-1764-1

    P-1764-1 Vacuum pump rocker seal is one of the frequently replaced spare parts for B-R Company’s vacuum pump. B-R vacuum pump has the characteristics of simple use and high work efficiency. It has few moving parts, only the rotor and slide valve (completely sealed in the pump cylinder). The air space at the exhaust end of the vacuum pump gradually decreases, allowing air to enter the exhaust valve (spring loaded disc check valve) through the exhaust hole.
  • AST solenoid valve GS021600V

    AST solenoid valve GS021600V

    The AST solenoid valve GS021600V is a kind of plug-in valve is equipped with a CCP230M coil and can be used as a solenoid valve with different functions. The electromagnetic valve is installed in the emergency trip system to check some operating parameters of the steam turbine. When these parameters exceed their operating limits, the system will issue a trip signal to close all steam inlet valves of the turbine to protect the safety of the unit.
  • AST/OPC solenoid valve SV4-10V-C-0-00

    AST/OPC solenoid valve SV4-10V-C-0-00

    The AST/OPC solenoid valve SV4-10V-C-0-00 is a valve that is opened or closed by electromagnetic force. Used in gas or liquid circuits. There are many types of structures, but the principle of action is basically the same. When the control circuit inputs an electrical signal, a magnetic signal is generated in the solenoid valve. This magnetic signal drives the electromagnet to generate an action, corresponding to the opening and closing of the valve.
  • EH oil main pump PVH074R01AB10A250000002001AE010A

    EH oil main pump PVH074R01AB10A250000002001AE010A

    EH oil main pump PVH074R01AB10A250000002001AE010A has a flexible and compact design, providing 250bar (3625psi) connection performance and 280bar (4050psi) operation performance in the load sensing system. This design is suitable for higher performance levels required by power intensive machinery to ensure long service life. The pump body has a net weight of 45KG and must be installed horizontally. The high-pressure fire-resistant fuel system is equipped with two PVH074 EH oil pumps, both of which are pressure compensated variable piston pumps. When the system flow changes, Causing an increase or decrease in system oil pressure, the pressure compensator will automatically adjust the plunger stroke and adjust the system pressure to the set value.