page_banner

Transmitter

  • Online Hydrogen Leak Detector KQL1500

    Online Hydrogen Leak Detector KQL1500

    The Online Hydrogen Leak Detector KQL1500 produced by our company is a precision instrument specially used for gas leak detection. It can be widely used in electric power, steel, petroleum, chemical industry, ships, tunnels and other places, and can be used for online monitoring of the leakage of various gases (such as hydrogen, methane and other combustible gases). The instrument adopts the most advanced sensor technology in the world, which can simultaneously conduct multi-point real-time quantitative monitoring on the parts requiring leak detection. The whole system is composed of a host and up to 8 gas sensors, which can be flexibly controlled.
  • LVDT Transmitter LTM-6A

    LVDT Transmitter LTM-6A

    The LVDT Transmitter LTM-6A is suitable for TD series six wire displacement sensors, with functions such as one key zero to full, sensor disconnection diagnosis, and alarm. LTM-6A can reliably and accurately convert the displacement of LVDT rods into corresponding electrical quantities. It has a MODBUS interface and can communicate with other devices, becoming a truly intelligent local device.
  • LJB1 type zero sequence current transformer

    LJB1 type zero sequence current transformer

    LJB1 type I/U Transducer (also called current transformer) can directly convert a large current into a small voltage signal output. It is used in systems with rated frequency 50Hz and rated voltage 0.5KV or less. The transducer input signal for computers, electrical measuring devices, and protective devices.
  • Active/Reactive Power (Watt/ Var) Transducer S3(T)-WRD-3AT-165A4GN

    Active/Reactive Power (Watt/ Var) Transducer S3(T)-WRD-3AT-165A4GN

    Active/Reactive Power (Watt/ Var) Transducer S3(T)-WRD-3AT-165A4GN is an instrument that can convert the measured active power, reactive power and current into DC output. The converted DC output is linear proportional output and can reflect the transmission direction of the measured power in the line. The transmitter is applicable to various single and three-phase (balanced or unbalanced) lines with frequencies of 50HZ, 60HZ and special frequencies, equipped with appropriate indicating instruments or equipment, and can be widely used in power plants, power transmission and transformation systems and other places with high requirements for power measurement.
  • GJCF-15 APH Gap Control system Signal Transmitter

    GJCF-15 APH Gap Control system Signal Transmitter

    GJCF-15 APH Gap Control system Signal Transmitter and the Gap Sensor Probe GJCT-15-E are used together to process the signal measured by the probe, and after a comprehensive judgment, an execution command is issued to start the power circuit, so that the sealed sector plate rises, falls or Emergency lift to the upper limit position. It is suitable for detecting the displacement of the air preheater rotor in motion under high temperature and harsh environment.

    GJCF-15 APH Gap Control system Signal Transmitter is used in the seal clearance control system of air preheater. The key problem of the system is the measurement of preheater deformation. The difficulty is that the deformed preheater rotor is moving, and the temperature in the air preheater is close to 400 ℃, and there are a lot of coal ash and corrosive gas in it. In such a harsh environment, it is very difficult to detect the displacement of moving objects.